PENENTUAN KADAR OKSIGEN TERLARUT MENGGUNAKAN SENSOR POLAROGRAFI BERMEMBRAN PLASTIK

Authors

DOI:

https://doi.org/10.18269/jpmipa.v2i2.34920

Keywords:

membrane plastic, polarographic, steady state,, Winkler method.

Abstract

Plastic membrane sensor for polarographic oxygen measurement has been investigated. The Probe was constructed of: Pt as a working electrode; Ag AgCl as a reference electrode and an auxiliary electrode; solution of KCl as an electrolyte solution; plastic wrap (thickness 72.7 m) as a membrane; and polyester polymer as a body of sensor. It was found that the polarographic oxygen sensor plastic membrane probe was suited for determination of dissolved oxygen with an optimum operating characteristics at applied voltage of  –0.65 V and solution KCl 30% as an electrolyte. The probe showed that reduction current achieved steady state after 75 seconds. The standard calibration curve (concentration – current) showed that the linear relationships were achieved for dissolved oxygen in the range of 1.0 – 30.6 ppm. The analytical performance characteristics of the probe were: precision 0.87% – 30.0 %; calibration sensitivity 0.17 ppm/A; analytical sensitivity 0.56 – 0.84 ppm/A; and detection limit 0.8 ppm. The t- test and F-test at 95% confidence level showed that there was no significant difference between the determinations of dissolved oxygen by polarographic oxygen sensor membrane plastic and by Winkler method.  

Downloads

Download data is not yet available.

Author Biography

  • Hokcu Suhanda, Indonesia University of Education

    Chemistry

References

Bret, C.M.A. & Bret, A.M.O. (1993), Electrochemistry. Oxford University Press, Oxford, New York and Tokyo.

Caulcutt, R. & Boddy, R. (1983), Statistics for Analytical Chemist. 1nd ed., Chapman and Hall Ltd, London.

Davies, P.W. & Brink, F. (1945), Microelectrodes for measuring local oxygen tension in animal tissues. Rev. Sci. Instr., 13: 524.

Dietz, H., Haecker, W., Jahnke, H. (1977), Electrochemical sensors for the analysis of gases. Vol 10: 1-90.

Fatt, I. (1978), Polarographic Oxygen Sensor: Its theory of operation and its application in biology, medicine, and technology. CRC Press, California.

Gnaiger, E. & Forstner, H. (1993), Polarographic Oxygen Sensors: Aquatic and physiological applications. Springer-Verlag, Berlin.

Hahn, C.E.W. (1993), Techniques for measuring the partial pressures of gases in blood. J. Phys., 14: 783-781.

Hale, J.M. & Hitchman, M.L. (1993), Some considerations of the steady-state and transsient behaviour of membrane-cover dissolved oxygen detectors. J. Electroanal. Chem., 107: 281-294.

Hibbert, D.B. & James, A.M. (1984), Dictionary of Electrochemistry. 2nd ed., The Macmillan Press LTD., London.

Hitchman, M.L. (1978), Measurement of Dissolved Oxygen. Vol. 49, John Wiley & Sons, New York.

Jensen, O.J., Jacobsen, T. & Thomson, K.J. (1978), Membrane-covered oxygen electrodes. J. Electroanal. Chem., 87: 203-211.

Downloads

Published

30-12-2001

How to Cite

PENENTUAN KADAR OKSIGEN TERLARUT MENGGUNAKAN SENSOR POLAROGRAFI BERMEMBRAN PLASTIK. (2001). Jurnal Pengajaran Matematika Dan Ilmu Pengetahuan Alam, 2(2), 67-79. https://doi.org/10.18269/jpmipa.v2i2.34920